Data Center Perforated Floor Tiles

We have models that can lift perforated and carpeted floor tiles.
Data center perforated floor tiles. In data centers isolated air conditioning zones are often associated with raised floors. Data center perforated tiles for cooling servers there is a lot to consider with perforated tiles in data centers and depending on who you talk to you will get different answers. The server floor in a data center is typically built on a raised floor with cold air being pumped under the floor by large crah computer room air handlers or crac units computer room air conditioners. We also carry wall mounted brackets to properly stow these devices.
A limited capacity to deliver cold air can adversely affect your overheated equipment. Data center airflow solutions perforated panels standard and directional air grates. Explore other data center products. Data center product line brochure.
Data center raised floor tiles. Other panels accessories. Perforated panel is specially designed for ventilation through below floor space up to the equipments applied for under floo. High flow access floor tiles high flow raised access floor tiles range from 32 to 66 perforation models delivering more than twice as much cool air in your cold aisle.
Anti static hpl raised floor. Our heavy duty tile lifters provide safety versatility and ease to lift solid floor tiles with up to 75lbs. Intelligent air flow raised floor data center other panels accessories. Until now only 25 open area perforated panels have been available.
As today s data center generates more heat load so has the need increased to deliver more cooling. The high flow floor tiles are available in 55 and 66 perforation models to deliver over twice as much cool air in your cold aisle exactly. Finally in a ved data center where all bypass leaks are sealed off and the raised floor joints themselves have less than 0 1 leakage then significantly higher under floor static pressure levels can be achieved for greater flow per tile thereby reducing the tile count requirement for high. 203 north columbia street covington la.
A limited capacity to deliver cold air can adversely affect your overheated equipment. Floor finishes learn more. Access floor systems inc. Heavy duty equipment panel learn more.
Published flow specs for tate brand tiles using 90 cfm per kw for blades and 155 cfm for 1 2 u servers. Perforated floor tiles are placed beneath computer systems to channel cool air directly into them. Data center flooring high performance access floor tiles for new and existing raised floor systems. Until now only 25 open area perforated panels have been available.