Ditra Heat Floor Temperature Sensor

Long cable comes with one temperature sensor.
Ditra heat floor temperature sensor. The second sensor can be connected in case of damage to the first sensor without. Where a waterproof floor is required all ditra heat and ditra heat tb seams and floor wall transitions must be sealed with kerdi band using unmodified thin set mortar. Do not place furniture or mats over the floor temperature sensor as they could act as insulation and lower the temperature of the floor warming system therefore causing the floor to feel cooler. Record your test results on the heating cable tests log on page 30 of the ditra heat installation handbook.
The second sensor can be connected in case of damage to the first sensor without. Test 4 temperature sensor. The dhehk120134 is a twisted pair heating cable the dhehk120134 is a twisted pair heating cable designed specifically for use with the ditra heat membrane for interior floor warming applications. The ditra heat thermostat has a built in gfci.
Both floor temperature sensors are installed within the tile assembly. Futons mattresses floor level furniture pillows etc. Slide the black wire behind the l1 terminal screw and tighten it with a flat head screwdriver. One sensor is connected to the thermostat while the other is stored in the thermostat electrical box.
Both floor temperature sensors are installed within the tile assembly. Vapor barrier on crawl space floors according to regional building codes. Floor temperature sensors may not be threaded through the same conduit as the cold lead. As such there are line and load terminals on the back of it.
This 120 volt 444 0 ft. Also perform the floor temperature sensor test for both sensors. The thermostat features a 5 ma built in ground fault circuit interrupter gfci with indicator light and includes a floor temperature sensor. One sensor is connected to the thermostat while the other is stored in the thermostat electrical box.
Areas of application over any even and structurally sound double. Why are two floor temperature sensors provided with the schluter ditra heat system. Ditra heat e rt is a programmable touchscreen thermostat used to control the ditra heat e hk heating cables either 120 v or 240 v. Why are two floor temperature sensors provided with the schluter ditra heat system.
Area rugs are not recommended over the ditra heat system. Thread the heating cable cold lead through a conduit where required by code from the base of the wall to the thermostat electrical box. Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.