Domestic Floor Loading Uk

This number tells you the total load capacity of your floor.
Domestic floor loading uk. For example historically uk office buildings have been designed and marketed with live loadings of 3 5 4 0 kn m2 however this may be an over provision. Concentrated load kn 1. 54 x 269 14 526 kg 32 024 lb. There are three general types of ground floor construction.
Office rooms in i hostel hotels hospitals and business building with separate store. For more information see. Given in bs 5268 7 1 which is a uniformly distributed load of 1 5kn m for spans greater than 2400 mm and 3 6 kn load per metre width of floor for spans less than 2400 mm to ensure that very small joist sizes do not result from the calculations for. All the figures are based on normal domestic floor loadings where the floor construction is typically 18 25mm floor boards sheets with up to 12 5mm thick plasterboard and skim underneath.
Udl load kn m 2 ad free. The loading in workshops warehouses and factories varies considerably and so these loadings under the terms light medium and heavy are introduced in order to allow fon more economical designs but the terms have no special meaning in themselves other than the live load fon which the relevent floor is designed. Steelbeamcalculator co uk has a shopper approved rating of 4 7 5 based on 1188 ratings and reviews. To ensure a level finish to the floor a layer of screed is added over the top of the concrete which consists of sand and cement.
This table uses commonly available uk regularised. 2attic loads may be included in the floor live load but a 10 psf attic load is typically used only to size ceiling joists adequately for access purposes. Uk site usa site. A typical way of constructing a solid floor would be to provide a base of hardcore with sand blinding with a layer of concrete over that.
Bathrooms and toilets in all types of buildings. If the example floor is 6 by 9 metres 20 by 30 feet the total area is 54 square metres 600 square feet. Get vip membership now. 2 5 kn m2 for floors above ground floor and 3 0 kn m2 at or below ground floor over may be more appropriate with 7 5 kn m2 over 5 of the floor area to allow for future flexibility.
For any other situation these tables may not be appropriate and you should refer to the. However if the attic is intended for storage the attic live load or some portion should also be considered for the design of other elements in the load path. Span tables domestic floor joists. In the uk and much of europe live loads are expressed as kilo newtons per square metre kn m2 while in the us the unit is pounds per square foot psf.