Dry Floor Waste Nsw

Automatic fire sprinkler system design and installation domestic water supply pdf 191 64 kb all metropolitan and regional areas in nsw.
Dry floor waste nsw. Itry bi residential wet area floor wastes ib 061 2016 2 there are however local health laws that each local government administers and which. Diagrams to support this matter can be found in the hia information sheet of the same name as this article. Since it would be in use very infrequently it would have no p trap. A dry floor waste discharges the water directly into the ground just outside the room because the amount of wastewater usually from.
All dry cleaners have a legal responsibility to protect their staff and the environment from these chemicals. 4 6 7 floor waste gullies 4 6 7 6 removable grate floor waste gullies shall be installed with an accessible removable grate and have a riser of not less than dn 80 to finished surface level. As the purpose of providing a floor waste gully in these circumstances is to ensure the proper functioning of the sanitary drainage system rather than. It is also important to note that despite whether a bathroom is on a ground floor or first floor of a house the wet area provisions including installing floor wastes if required are the same.
You should have a grate or flap on the exit to exclude vermin though. Wet area rooms of class 2 3 part 4 buildings require floor wastes regardless of the type of shower only to prevent the potential for damage to other sole. Speaking of nsw many many houses have a dry waste in the laundry floor which simply exits over the ground outside. Perchloroethylene perc dry cleaning solvent and the waste produced from the dry cleaning process are suspected carcinogens and are toxic to the environment.
Another way of taking away water on the floor is a dry floor waste. Where the sole function of the floor waste gully is to dispose of water spillage and wash down water a minimum dn 50 riser may be used. Table 2 1 of as3740 page 11 also refers to bathrooms and laundries requiring a floor waste in accordance with volume 1 of the bca in which case the floor is to be waterproofed and drained. These can be placed in other rooms containing plumbing fixtures such as the laundry or toilet to assist in draining water from the floor.
Floor wastes are not required in wet area rooms of class 1 buildings unless the area contains an unenclosed shower in which case the shower waste doubles as the floor waste. Filled ground pdf 218 84 kb all installations in nsw. Complying floor wastes pdf 228 39 kb all metropolitan and regional areas in nsw. An untrapped floor waste is installed it is considered plumbing work and shall be installed in accordance with as nzs 3500 2 clause 13 26.